CIT Rafaela-Energía, medio ambiente e industria
URI permanente para esta colecciónhttps://hdl.handle.net/20.500.14399/326
Examinar
Examinando CIT Rafaela-Energía, medio ambiente e industria por Materia "inverter"
Mostrando 1 - 1 de 1
- Resultados por página
- Opciones de ordenación
Ítem Single and Multiple Open-Switch Fault Diagnosis in Electric Drives via Zero-Current Interval Analysis(Universidad Nacional de Rafaela, 2026-03-01) Venghi, Luis Esteban; Aguilera, Facundo; De la Barrera, Pablo Martín; De Angelo, Cristian HernánIn this work, a new and simple method for open-switch fault diagnosis in electric drives based on zero-current detection is proposed. The approach requires only two phase current sensors, with the measured currents being normalized and separated into positive and negative half-cycles. A variable-sample-time moving average is introduced for post-processing the signals. Zero-current interval detection is employed to diagnose both single and multiple open-switch faults. The proposed method was experimentally validated under various fault conditions, including single-switch, crossed-switch, full-leg, and two upper- or lower-switch open-circuit faults. Experimental results demonstrate that, despite its simplicity and ease of implementation, the method reliably detects all single and double open-switch fault scenarios in less than one electrical cycle, across different motor operating conditions.